Troubleshooting guides · Boilers

Boiler not giving hot water? Troubleshooting assistant

Answer two questions and we'll tell you the most likely reasons your boiler isn't giving hot water, what you can safely check yourself (display, pressure gauge, reset) and when you need to call a technician.

1. What do you see on the boiler?
2. Since when and how does it happen?
3. Your details (optional)

They're only added to the WhatsApp message if you choose to send it. They aren't stored on this website.

First of all, for safety. If you smell gas: close the gas valve, don't switch any lights or appliances on or off, open doors and windows, leave the premises and, from outside, call your gas distribution company's emergency number (Nedgia: 900 750 750) or 112. If the boiler is dripping water onto electrical parts, making loud noises or smells of burning, disconnect it and don't reset it. Don't remove the casing: inside there is gas and live parts.

What you can safely check yourself

  • Look at the display and note down any code, along with the make and model of the boiler.
  • Check the pressure on the gauge: when cold, roughly between 1 and 1.5 bar.
  • Check that the gas valve is open and that there is power at the boiler's socket. If you find it closed and don't know why, or it has been sealed, don't open it: call the distribution company or an installer.
  • Reset only once. If it locks out again with the same warning, don't keep trying.
  • Take a photo of the display and the pressure gauge and send it to us: that's enough for us to advise you.

What a technician does

  • Reading the error code with the manufacturer's technical documentation and checking the ignition sequence.
  • Combustion analysis and checking the ignition electrode, fan and gas valve.
  • Checking the flow sensor, three-way valve and hot water heat exchanger (descaling or replacement).
  • Checking and recharging the expansion vessel and locating leaks in the circuit.
  • Mandatory periodic maintenance under the RITE, with its logbook.

FAQ

What pressure should the boiler be at?

When cold, the pressure gauge needle should be roughly between 1 and 1.5 bar; it's normal for it to rise a little as it heats up. Below 1 bar many boilers lock out, and close to 3 bar the safety valve opens.

Can I top up the boiler pressure myself?

Yes. With the boiler cold, slowly open the filling valve and close it when it reaches 1.2–1.5 bar. If you have to top up often, there's a leak or a problem with the expansion vessel that needs checking.

What should I do if an error code appears?

Note it down together with the make and model, and reset the boiler once. If it comes back, don't keep trying: each code points to a specific fault and repeated resets won't fix it. Send us a photo of the display.

Why does the heating work but not the hot water?

Because the boiler fires up fine but doesn't detect the hot water demand or doesn't divert it to the tap. It's usually the flow sensor, the three-way valve or a scaled-up hot water heat exchanger.

How often should the boiler be serviced?

The Regulation on Thermal Installations in Buildings (RITE) requires periodic maintenance by an authorised company. As well as being mandatory, it prevents many of these faults and extends the life of the boiler. It is not the same as the periodic inspection of the gas installation, which the distribution company carries out every 5 years (RD 919/2006, ITC-ICG 07).

Other guides you might find useful

Talk to a technician

This guide is for guidance only and does not replace an inspection by a qualified professional. Every installation has its own particularities.

Contact

Let's talk about your next project.

680 42 72 61

Monday to Friday, 8:00 to 17:00. Carrer de Núria, 97, local, Terrassa.