Heating not working? Diagnostic assistant
Answer two questions about what you notice in the radiators or underfloor heating and in the boiler. The assistant explains the most likely causes, what you can safely check yourself and when it's best to have a technician look at it.
What you can safely check yourself
- Check that the boiler is in heating mode and the thermostat has batteries and a set point above the room temperature.
- Check the pressure gauge and top up to 1–1.5 bar (cold) using the filling valve, closing it when you've finished.
- Bleed the radiators with the heating off and check the pressure again afterwards.
- Fully open the valves and thermostatic heads on the cold radiators.
- Press the boiler reset button once and write down the error code if it reappears.
- Check the boiler's circuit breaker in the electrical panel and that the plug or switch has power.
What a technician does
- Checks the circulation pump, three-way valve and expansion vessel charge.
- Locates leaks in the circuit and checks the safety valve and automatic air vent.
- Balances the system by adjusting the lockshield valves so water reaches every radiator.
- Cleans sludge from the circuit and the heat exchanger when dirt is reducing performance.
- Carries out the periodic inspection required by the RITE, including combustion analysis.
FAQ
What pressure should the boiler show for the heating?
With the system cold, it should normally be between 1 and 1.5 bar. When hot it rises a little, but it shouldn't get close to 3 bar, which is when the safety valve opens. If it drops below 1 bar, you can top it up using the filling valve.
Why is a radiator hot at the bottom and cold at the top?
It's almost always air trapped at the top of the radiator. Bleeding it with the heating off usually solves it. Afterwards, check the pressure and top up if it has dropped.
Why do I have to top up the boiler so often?
A sealed circuit shouldn't lose water. If you need to top up every few days or weeks, there's a leak or a problem with the expansion vessel or safety valve. Have a technician check it, because constant topping up introduces oxygen and limescale into the circuit.
The hot water works, but the heating doesn't. What could it be?
If the hot water is fine, the gas and burner are working. The most common causes are the boiler being in summer mode, the thermostat not calling for heat, or a faulty three-way valve or circulation pump.
How often should the boiler be serviced?
The RITE (Spanish thermal installations regulation) requires periodic maintenance by a certified company, at the frequency it sets according to the unit's output and type. A serviced boiler breaks down less, uses less energy and runs more safely.