Troubleshooting guides · Plumbing
Low water pressure or no water? Troubleshooting assistant
Answer two questions about where and when you notice the low pressure and we'll explain the most likely causes. You'll also see what you can safely check yourself before calling a technician.
What you can safely check yourself
- Check with the water company whether there are cuts or incidents in your area.
- Check that the main valve of your installation (after the meter) and the angle valves are fully open. The one before the meter belongs to the water company: don't tamper with it.
- Clean tap aerators and shower heads with vinegar.
- Close all taps and check whether the meter keeps turning to detect leaks.
- Check that cisterns aren't constantly leaking water.
- Note when it happens, at which points and whether there are noises, to explain it to the technician.
What a technician does
- Measures static and dynamic pressure with a gauge and adjusts or replaces the pressure reducing valve.
- Cleans or replaces main filters and checks the stop valves.
- Locates and repairs leaks, including hidden ones in concealed pipework.
- Checks the booster set: pressure switch, pump and expansion tank charge.
- Assesses replacing old pipework or installing a water softener.
FAQ
What water pressure is normal?
An indoor installation usually runs at roughly 2 to 4 bar. Below 1.5 bar you'll notice poor flow, and above 5 bar it's worth fitting or adjusting a pressure reducing valve to protect taps and equipment.
How do I know if I have a leak?
Close all taps and make sure no equipment is using water. Then look at the meter: if the dial or numbers keep moving, there's a leak somewhere in the installation. A leaking cistern is a very common cause.
Why is there low flow at just one tap?
It's almost always the aerator at the tap outlet clogged with scale or particles. Unscrew it, clean it or soak it in vinegar for a few hours. If nothing changes, check the angle valve and, if that's fine, it may be the tap cartridge.
What is a pressure reducing valve and why does it fail?
It's a valve fitted after the meter to limit the pressure entering the installation. Over time, scale and dirt can jam it or knock it out of adjustment, causing low pressure or, conversely, excessive pressure and water hammer in the pipes.
Why is the water cloudy after a supply cut?
When the supply is restored, sediment in the mains is stirred up. Running the cold water for a few minutes is usually enough. If the colour persists or it smells bad, don't drink it and contact the water company.
Other guides you might find useful
- Electric water heater not heating?
- Water softener not removing limescale?
- See all troubleshooting guides
This guide is for guidance only and does not replace an inspection by a qualified professional. Every installation has its own particularities.