Troubleshooting guides · HVAC

Air-to-water heat pump not heating or showing an error? Troubleshooting assistant

Answer two questions about your air-to-water heat pump and the assistant will explain what might be happening and what you can safely check. If you need a technician, it helps you describe the problem in detail.

1. What's wrong with your heat pump?
2. Have you noticed anything else?
3. Your details (optional)

They're only added to the WhatsApp message if you choose to send it. They aren't stored on this website.

First of all, for safety. If you notice a burning smell, see sparks, water is coming out onto electrical parts or the RCD trips again and again, disconnect the unit at its circuit breaker in the panel and do not switch it back on. If there is smoke or fire, get out and call 112. Do not open the casing or tamper with the refrigerant circuit: refrigerant gases can only be handled by a certified company.

What you can safely check yourself

  • Check the operating mode, set points and timer programme on the controller.
  • Check the hydraulic circuit pressure on the gauge and write it down.
  • Check that the heat pump's circuit breakers in the electrical panel are switched on.
  • Keep the outdoor unit clear, with nothing blocking the air inlet or outlet, if it is accessible without any risk of falling.
  • Write down any error code along with the unit's brand and model.

What a technician does

  • Interprets the error code using the manufacturer's documentation and checks the sensors and communication between units.
  • Cleans the water filter, checks the flow rate and expansion vessel, and bleeds the hydraulic circuit.
  • Checks the refrigerant circuit, operating pressures and refrigerant charge as a certified company.
  • Adjusts the heating curve, the anti-legionella cycle and the use of the backup heater to improve performance.
  • Carries out the periodic maintenance required by the RITE (Spanish thermal installations regulation).

FAQ

Is it normal for the outdoor unit to give off steam and stop in winter?

Yes. In cold, damp weather the outdoor coil frosts over and the unit runs a periodic defrost: it stops for a few minutes, releases steam and water, and then starts heating again. It's only a problem if the ice builds up and doesn't go away.

Why don't the radiators or floor feel as hot as with a boiler?

An air-to-water heat pump works with water at a lower temperature to perform better, especially with underfloor heating. That's why the emitters feel lukewarm even when the installation is working properly. What matters is that the room reaches the desired temperature.

What pressure should the hydraulic circuit gauge show?

With the system cold it's usually between 1 and 2 bar, but the exact value depends on the manufacturer and the installation. If it drops often there may be a leak or a problem with the expansion vessel, and it's best to have a technician check it.

What is the anti-legionella cycle?

It's a periodic heating of the domestic hot water tank to a high temperature to prevent the growth of legionella bacteria. It's necessary and usually uses the backup heater, so it increases consumption somewhat while it runs.

Can I recharge the heat pump's gas myself?

No. Refrigerant gases can only be handled by an authorised company. Also, if gas is low it's because there's a leak that must be found and repaired before recharging.

Other guides you might find useful

Talk to a technician

This guide is for guidance only and does not replace an inspection by a qualified professional. Every installation has its own particularities.